Q. "For an unvented building with no insulation above the sheathing, how about using Wooden fibreboard in between the rafters directly underneath and involved with the sheathing?"

"R-19 batts are very air permeable, and on long unobstructed rafter bays you might have pretty a stack effect. It doesn't take a enormous number of air leakage to deliver some drying there. Also, if the batts are unfaced or kraft-faced, the drying towards the inside could be considerable.

Altering the Intelo membrane to glued & taped OSB or Plywood with a support cavity underneath product of framing lumber does make the assembly less difficult to develop.

I've an unfinished attic, with cathedral ceiling, no insulation presently. in 5-10years we will likely be including dormers, but in the meantime i wish to include insulation and drywall in The best, most reversible/salvageable manner. My plan is to hang 2 levels of 2 inch polyiso beneath the rafters, taped with staggered seams leaving the rafters vacant, so effectively a vented assembly. I have included blocking to the floor joists and can make the polyiso constant within the knee partitions. I believed I'd personally include furring strips in addition to the insulation then cling drywall, thinking that the furring strips would develop an airgap, enabling the foil to work as a radiant barrier.

Joe Lstiburek: "A vented attic, wherever insulation is put on an air-sealed attic floor, is Among the most underappreciated making assemblies that We now have inside the record of setting up science."

Doug I agree, too many wrongs "overthinking" and overdoing. I once needed to resupply a doctor creating an plane with dozens of AN plane bolts as they have been tightened to The purpose of breaking the bolts. A lot less is a lot more at times... Along with the KISS rule.

Make sure you enter any prior references (preceding clientele) that you may have worked with separated by typing Enter

To avoid moist inside air from getting in contact with cold surfaces near the ridge, You will need a authentic air barrier and a real insulation layer. The proper way to fix this problem is to show the rafter bays -- either from over or beneath, It can be your decision -- and pull out the fiberglass insulation. Put the fiberglass in a dumpster. Then fill the rafter bays with spray polyurethane foam.

If you put in 2x4s (or 2x3s on edge, set up with long screws) perpendicular for the rafters, my link you might tackle the majority of the thermal bridging concern without the necessity to incorporate a layer of rigid foam.

Martin, re: altering the attic around the 2nd Tale bedrooms into a conditioned attic and sealing the soffit vents.... Just before this hottest plan about insulating with rigid foam on top of the cathedral ceiling, we were planning to cut a ridge vent in to the gable ridge, in order to satisfy air flow code specifications. At present We've got eave vents moreover two rather useless gable vents, just one on either side.

I haven't got a great deal of room over or under the roof composition for insulation / venting. Would a flash / batt unvented assembly work less than The one sheathing deck? My insulator has done quite a few of these locally.

My home built in 63 below in Ohio includes a cathedral ceiling with no air flow. Actually there a lot of cross-supports running perpendicular to the key joists and also other framing factors that would make this unfeasible. So I need to make it browse around here an effective unvented roof. 50 % of the roof has 2x8 joists and the opposite 50 percent has 2x12s. At this time You will find there's membrane covering (rubber) that's labored well for more than twenty years but is showing signs of deterioration and may have to have replacing before long. Having performed remodeling on The within and going for walks about the roof I understand that a great deal of the sheeting ought to be replaced along with the little insulation that is there now. We've had condensation difficulties in past times so I now there are air infiltration and bridging concerns.

The GBA website won't deliver custom specifics. That's what an architect or an engineer is for; I advise that you use one particular.

But If your installer Get More Information is conscientious, and also the rafter bays seriously are dense-packed, my guess is that every thing will be high-quality.