I've a thing for blueskin, like a the two an air and vapour barrier, but additionally it'll act as a seal for the screws that keep all the things down. In reference to the vaulted schematics on This page, it displays vapour/air barrier along with insulation, which received me pondering. Nearly as good as I am putting in components, no person is ideal, and an air leak may well acquire concerning XPS seams. As soon as ANY humidity receives right down to decreased sheathing, it can be match more than.

If you wish to use just one style of insulation in unvented rafter bays, you happen to be restricted to spray polyurethane foam. Yet another probability, of course, is to create your roof with structural insulated panels (SIPs).

Many thanks for finding the thread previously mentioned...note that in write-up #seventeen, Robert Riversong talks about the "vented over roof". I agree with you that this process deserves some interest for cathedral ceilings.

Q. "If I install a polyethlene sheet among the bottom in the batting and the sheetrock [it would be connected for the purlins], would not this be an interior vapor barrier?"

For instance that a certain setting up observe results in a twenty% failure level. That practice will be thoroughly unacceptable to builders, who don't desire callbacks or headaches. But that practice would nonetheless result in 80% of customers becoming happy.

I am guessing that neither of those particulars accurately suits your needs. But as I famous before, If you prefer a customized detail, you probably need to have to hire an architect or an engineer. Very good luck.

I agree with you: I would love to see more info on this problem. I'm not conscious of any failures that have occurred in properly dense-packed unventilated rafter bays.

Set up a layer of shut-cell spray foam versus the underside from the roof sheathing, and fill the rest of the rafter cavity with an air-permeable insulation. Yet again, this sort of assembly is made to dry to the interior, Hence the assembly really should in no way contain an inside polyethylene vapor barrier.

No matter whether Learn More Here you choose to really make it vented or unvented, get the details right — simply because every single cathedral ceiling offers opportunities to help make big mistakes

Probably the solution to go would be to settle for 4" of froth above the cathedral ceiling, rather then 8" of foam, rather than continue the foam around the vented attic. There'll be a weird jog while in the roof line where by the foam starts, but it can largely only be noticeable within the back of the house, not from the street.

Martin, thanks to your superb and well timed assistance, we at the moment are headed toward a solution of rigid foam around the exterior in the ceiling. Thank you for pointing me On this new and improved direction. We remain Operating out some details, for instance...

Several spray foam roofing contractors within our market are touting their capacity make improvements to performance on previous sizzling tar and graveled flat roofs by introducing three to 4 inches of shut cell spray foam. Many of these outdated homes are flat roofs joisted with dimensional lumber, with parapets a fantastic read and also have stucco vents Lower into the rim joists.

The high density fiberglass is so a lot more dense in comparison to the medium and reduced density fiberglass that it looks like it should really decrease the possible for convection within the batts, but at two to three moments the cost of medium density fiberglass batts the attain might be nominal rather than worth the added cost. Thanks for reference sharing your skills,

A. The air barrier can be quite a vapor barrier, since the rigid foam can be very likely to be considered a vapor barrier (or near to it) in any circumstance.